ADAS Subroutine e4chkb
SUBROUTINE E4CHKB( IUNIT , NBSEL , IBSEL ,
& IZ0IN , IZ0 ,
& LOPEN , IRCODE
& )
C-----------------------------------------------------------------------
C
C ****************** FORTRAN77 SUBROUTINE: E4CHKB *********************
C
C PURPOSE: TO CHECK THE SELECTED BLOCK (IBSEL) OF DATA EXISTS IN THE
C INPUT DATA SET AND IF SO IT REPRESENTS THE ENTERED VALUES OF
C 'IZ0IN' (NUCLEAR CHARGE OF SELECTED IONISING ION ELEMENT).
C
C IT ALSO CLOSES THE INPUT DATA SET ALLOCATION IF OPEN.
C
C CALLING PROGRAM: SPZD
C
C SUBROUTINE:
C
C INPUT : (I*4) IUNIT = UNIT TO WHICH INPUT DATA SET IS ALLOCATED
C INPUT : (I*4) NBSEL = TOTAL NUMBER OF DATA-BLOCKS READ FROM INPUT
C DATA SET.
C INPUT : (I*4) IBSEL = INDEX OF DATA-BLOCK SELECTED FOR ANALYSIS
C
C INPUT : (I*4) IZ0IN = REQUESTED: NUCLEAR CHARGE OF ELEMENT
C INPUT : (I*4) IZ0 = INPUT FILE: NUCLEAR CHARGE OF ELEMENT
C
C I/O : (L*4) LOPEN = INPUT : .TRUE. => INPUT DATA SET OPEN.
C .FALSE. => INPUT DATA SET CLOSED.
C OUTPUT: ALWAYS RETURNED AS .FALSE.
C OUTPUT: (I*4) IRCODE = RETURN CODE FROM SUBROUTINE:
C 0 => NO ERROR DETECTED.
C 2 => DISCREPANCY BETWEEN REQUESTED ELEMENT
C AND THAT IN INPUT DATA FILE.
C 3 => SELECTED DATA-BLOCK OUT OF RANGE OR
C DOES NOT EXIST.
C
C (I*4) I4UNIT = FUNCTION (SEE ROUTINE SECTION BELOW)
C
C (C*80) DSNAME = NAME OF DATA SET OPENED
C
C ROUTINES:
C ROUTINE SOURCE BRIEF DESCRIPTION
C ------------------------------------------------------------
C E4FILE ADAS OPEN DATA SET FOR SELECTED ELEMENT
C I4UNIT ADAS FETCH UNIT NUMBER FOR OUTPUT OF MESSAGES
C
C AUTHOR: PAUL E. BRIDEN (TESSELLA SUPPORT SERVICES PLC)
C K1/0/37
C JET EXT. 2620
C
C DATE: 06/06/91
C
C UPDATE: 23/04/93 - PE BRIDEN - ADAS91: ADDED I4UNIT FUNCTION TO WRITE
C STATEMENTS FOR SCREEN MESSAGES
C
C UPDATE: 24/06/93 - PE BRIDEN - ADAS91: CHANGED I4UNIT(0)-> I4UNIT(-1)
C
C UPDATE: 1/11/94 - L. JALOTA - INCREASED SIZE OF DSNAME FOR UNIX.
C UNIX-IDL PORT:
C
C VERSION: 1.1 DATE: 25-5-95
C MODIFIED: TIM HAMMOND (TESSELLA SUPPORT SERVICES PLC)
C - PUT UNDER SCCS CONTROL
C
C VERSION: 1.2 DATE: 17-1-96
C MODIFIED: TIM HAMMOND (TESSELLA SUPPORT SERVICES PLC)
C - REPLACED SSZD WITH SPZD AND MINOR CHANGE TO FORMATS
C
C-----------------------------------------------------------------------
C-----------------------------------------------------------------------
C
C-----------------------------------------------------------------------
INTEGER IBSEL, IRCODE, IUNIT, IZ0
INTEGER IZ0IN, NBSEL
LOGICAL LOPEN